DLS reports data on a very wide range of particle sizes, sometimes for diameters spread over 4 to 5 orders of magnitude. Designed primarily for use with the BI-9000AT Correlator, it meets the most exacting requirements for both static (SLS) and Dynamic Light Scattering (DLS) applications in polymer and particle. However, transforming your data to volume is reasonable in this circumstance and this will get rid of this artifact peak. Dynamic light scattering instruments are easy to use and generate very appealing data. The BI-200SM Goniometer with precise stepper motor control of detector angle is the centre piece of Brookhavens modular research light scattering system. For such small material as yours I'd be considering a quartz or glass cuvette for better optical quality. Do you really have a sample size limitation here? This is almost certainly the cause of the apparent large (and false) peak at around 3.5 microns (flare from scattering from the wall of the cell). You're using the disposable 40 microliter cuvette. The intercept is pretty high at ~ 0.8 and this is another sign of good data. diffusion speed, DLS is a very sensitive technique for detecting these changes. I'm sure you'll agree! If you could increase your concentration by 100 or 1000 times then this may be helpful in giving more signal. The (automatic) attenuator is at 10 so this tells me that your material is either small, in low concentration or poor optical contrast (relative refractive index). What else can I see? I'll only comment on the intensity plot. The rate of fluctuations is directly related to the rate of diffusion of the molecule through the solvent, which is related in turn to the particles hydrodynamic radii. So your z-average is in the right ball-park. In dynamic light scattering (DLS), the time-dependent fluctuations in the scattered light are measured by a single photon counting module. Other shapes give large estimates for the diameter up to about 14 nm for a linear polysaccharide. This would give you an estimated diameter of 7.4 nm. This well established principle is used in dynamic light scattering (DLS), or also called photon-correlation spectroscopy, which is a widely popular and highly adaptable analytical method applied in different fields of life and material sciences, as well as in industrial quality control processes. Theoretical Basis for Light Scattering Light scattering is something that can be seen when light, typically monochromatic laser light, is scattered by objects oriented at random in solution. Again you don't tell me if this shape is reasonable or not. Dynamic Light Scattering (DLS) is a measurement method that offers a quick and easy technique for the sizing of submicron and nanoparticle. This gives an estimated hydrodynamic radius of ~ 3.7 nm for a globular protein.
#DYNAMIC LIGHT SCATTERING DLS SOFTWARE#
Again I can use the calculator in the Zetasizer software to estimate a size. This note outlines the main differences in results, technical specifications and system requirements for each technique. OK, now you're talking of a molecular mass ~ 70 kDa. NanoParticle Tracking Analysis (NTA) technique presents an interesting alternative to more typical Light Scattering techniques such as Dynamic Light Scattering (DLS).